This article discusses RS-232 cable length, grounding , marks and spaces.
DISCUSSION
MARKs and SPACEs All RS-232 signals (except grounds) will be above + 3 volts or below - 3 volts (commonly + or - 12 volts). The area between + 3 volts and - 3 volts is called the transition region. No RS-232 signal (excluding ground) should ever be stationary at a voltage in the transition region. If one is found between + 3 volts and - 3 volts, it is a definite indication of an issue. CABLE LENGTH One of the issues in an RS-232 installation is determining the length of cable to be used. Because capacitance increases with cable length and increased capacitance can eventually degrade the signal to the point where it will cause the loss of data integrity. The RS-232 standard very conservatively recommends that the maximum length of cable be 50 feet (unless special low capacitance cable is used) and that its total capacitance be limited to 2500 uf or less. However, this length can usually be doubled, tripled, and more depending on the BPS rate (the higher the BPS rate used, the shorter the cable may have to be). If a cable is over 50 feet and a length problem is suspected, try using a lower BPS rate. If the problem goes away, then try using a shorter or lower capacitance cable at the higher data rate. If the problem doesn't reappear then it must have been the longer cable. CABLE GROUNDING If long cables (over 50 feet) are used, the cable should be shielded. In this case the shield, SG (pin 7), and CG (pin 1) should be grounded to the chassis on only one side of the interface (either the DTE or DCE). |
Document Information | |
Product Area: | Computers; Peripherals |
Category: | Cables |
Sub Category: | SCSI |
Keywords: | HTS, CNFG |
Copyright © 2000 Apple Computer, Inc. All rights reserved.