TOPIC
DISCUSSION Hard Drive or DAT drives may need to have the termination resistors removed or made inoperative on certain configurations of multiple drive systems or Workgroup Servers. Below is a brief description of termination requirements for the different systems or Workgroup Servers. Refer to the graphics below for termination locations on the various drives. CPU Enclosure Termination -------------------- -------------------- ---------------------------- 660 AV/Centris 660AV All use the QFC Hard Drive needs Termination Q610 / Centris 610 enclosure PM 6100 W/S 60 W/S 6150 IIVX, II VI All use the Lego Hard Drive needs Termination Q650 / Centris 650 enclosure PM 7100 Q800, Q800 AV Uses one type of the Last drive in line needs of the Frigidaire Termination. Remove enclosure termination from all other drives installed, including DAT PM 8100 Uses one type of the Has two internal cables: W/S 8150 Frigidaire enclosure 1)Internal/external cable requires that all drives have no termination.Remove termination from all internal drives (termination is on cable) 2)The internal channel cable (max 1 drive only) requires termination Q900 Remove termination from all Q950 internal drives (termination W/S 95 is on cable) W/S 9150 HP DAT Drive ------------ ------------------------------------------------- | |<-Term PWR | | | |<-SCSI 2 | | | | |<-SCSI 1 | | \|/ \|/ \|/ \|/<-SCSI 0 | --- --- --- --- | | ____________________________/|\_________________ | | | O O O O | ------------------------------|------------------- Remove Jumper to Diable termination ->| Conner Drives ------------- ---------------------------------------- |----------------------------------------| | | | ----------- ----------- | | /|\ /|\ | | |-------------| | | | | | |<- Remove resistor packs to Disable termination. | --- | | / \ | | | | | | \ / | | --- | | | | | | | | | | | ---------------------------------------- Quantum Drives -------------- ---------------------------------------- |----------------------------------------| | | | ----------- ----------- | | /|\ /|\ | | |-------------| | | | | | |<- Remove resistor packs to Disable termination. | | | | | | | | | | | | | | | | | | | | ---------------------------------------- IBM Drives ---------- ---- | | Detail | |<-- Se Detail --- --- | \ | | --- | | | \ | | | | | | | \ | -------- -------- | | \ | | | \ ----------------------------- | \ |_| |_| |_| |_| |_| |_| |_| | \ /|\ /|\ /|\ /|\<-Term | | | | |<-SCSI 2 | PWR | | | |<-SCSI 1 \|/ ------------------------ |<-SCSI 0 Remove jumper to Disable termination Support Information Services |
Document Information | |
Product Area: | Computers |
Category: | Workgroup Servers |
Sub Category: | General Topics |
Copyright © 2000 Apple Computer, Inc. All rights reserved.